Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
2.
Clin Chem Lab Med ; 2023 Apr 21.
Article in English | MEDLINE | ID: covidwho-2303817

ABSTRACT

OBJECTIVES: To assess the long-term humoral immunity induced by booster administration, as well as the ability of binding antibody and surrogate virus neutralization tests (sVNT) to predict neutralizing antibodies (NAbs) against the SARS-CoV-2 Omicron variant. METHODS: A total of 269 sera samples were analyzed from 64 healthcare workers who had received a homologous booster dose of BNT162b2. Neutralizing antibodies assessed by sVNT and anti-RBD IgG measured with the sCOVG assay (Siemens Healthineers®) were analyzed at five timepoints; before and up to 6 months following the booster. Antibody titers were correlated with neutralizing antibodies against the Omicron BA.1 variant obtained by pseudovirus neutralization test (pVNT) as a reference method. RESULTS: While Wild-type sVNT percentage of inhibition (POI) remained above 98.6% throughout the follow-up period after booster administration, anti-RBD IgG and NAbs assessed by Omicron BA.1 pVNT showed respectively a 3.4-fold and 13.3-fold decrease after 6 months compared to the peak reached at day 14. NAbs assessed by Omicron sVNT followed a steady decline until reaching a POI of 53.4%. Anti-RBD IgG and Omicron sVNT assays were strongly correlated (r=0.90) and performed similarly to predict the presence of neutralizing antibodies with Omicron pVNT (area under the ROC: 0.82 for both assays). In addition, new adapted cut-off values of anti-RBD IgG (>1,276 BAU/mL) and Omicron sVNT (POI>46.6%) were found to be better predictors of neutralizing activity. CONCLUSIONS: This study showed a significant drop in humoral immunity 6 months after booster administration. Anti-RBD IgG and Omicron sVNT assays were highly correlated and could predict neutralizing activity with moderate performance.

3.
Int J Mol Sci ; 24(8)2023 Apr 14.
Article in English | MEDLINE | ID: covidwho-2294075

ABSTRACT

Severe forms of coronavirus 2019 (COVID-19) disease are caused by an exaggerated systemic inflammatory response and subsequent inflammation-related coagulopathy. Anti-inflammatory treatment with low dose dexamethasone has been shown to reduce mortality in COVID-19 patients requiring oxygen therapy. However, the mechanisms of action of corticosteroids have not been extensively studied in critically ill patients in the context of COVID-19. Plasma biomarkers of inflammatory and immune responses, endothelial and platelet activation, neutrophil extracellular trap formation, and coagulopathy were compared between patients treated or not by systemic dexamethasone for severe forms of COVID-19. Dexamethasone treatment significantly reduced the inflammatory and lymphoid immune response in critical COVID-19 patients but had little effect on the myeloid immune response and no effect on endothelial activation, platelet activation, neutrophil extracellular trap formation, and coagulopathy. The benefits of low dose dexamethasone on outcome in critical COVID-19 can be partially explained by a modulation of the inflammatory response but not by reduction of coagulopathy. Future studies should explore the impact of combining dexamethasone with other immunomodulatory or anticoagulant drugs in severe COVID-19.


Subject(s)
COVID-19 , Cytokines , Humans , SARS-CoV-2 , Critical Illness , COVID-19 Drug Treatment , COVID-19/complications , Dexamethasone/pharmacology , Dexamethasone/therapeutic use
4.
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology ; 2023.
Article in English | EuropePMC | ID: covidwho-2251531

ABSTRACT

Background : A SARS-CoV-2+Flu A/B+RSV Combo Rapid test may be more relevant than Rapid Antigen Diagnostic (RAD) tests targeting only SARS-CoV-2 since we are facing a concurrent circulation of these viruses during the winter season. Objectives : To assess the clinical performance of a SARS-CoV-2+Flu A/B+RSV Combo test in comparison to a multiplex RT-qPCR. Study Design : Residual nasopharyngeal swabs issued from 178 patients were included. All patients, adults and children, were symptomatic and presented at the emergency department with flu-like symptoms. Characterization of the infectious viral agent was done by RT-qPCR. The viral load was expressed as cycle threshold (Ct). Samples were then tested using the multiplex RAD test Fluorecare®ฏ SARS-CoV-2 & Influenza A/B & RSV Antigen Combo Test. Data analysis was carried out using descriptive statistics. Results : The sensitivity of the test varies according to the virus, with the highest sensitivity observed for Influenza A (80.8.% [95%CI: 67.2 - 94.4]) and the lowest sensitivity observed for RSV (41.5% [95%CI: 26.2 - 56.8]). Higher sensitivities were observed for samples with high viral loads (Ct < 20) and decrease with low viral loads. The specificity for SARS-CoV-2, RSV and Influenza A and B was >95%. Conclusions : The Fluorecare® combo antigenic presents satisfying performance in real-life clinical setting for Influenza A and B in samples with high viral load. This could be useful to allow a rapid (self-)isolation as the transmissibility of these viruses increase with the viral load. According to our results, its use to rule-out SARS-CoV-2 and RSV infection is not sufficient.

5.
Clin Chem Lab Med ; 61(9): 1670-1675, 2023 Aug 28.
Article in English | MEDLINE | ID: covidwho-2260668

ABSTRACT

OBJECTIVES: The BNT162b2 messenger RNA vaccine is highly effective in reducing COVID-19 infection, hospitalization and death. However, many subjects developed a breakthrough infection despite a full vaccination scheme. Since the waned efficacy of mRNA vaccines is correlated with the decrease of antibodies occurring over time, we aimed at evaluating whether lower levels of antibodies were associated with an increased risk of breakthrough infection in a cohort of breakthrough subjects that received three vaccine doses. METHODS: Total binding antibodies against the RBD of the S1 subunit (Roche Diagnostics, Machelen, Belgium) and neutralizing antibodies using the Omicron B.1.1.529 variant pseudovirus were measured. Based on individual kinetic curves, the antibody titer of each subject was interpolated just before the breakthrough infection and compared to a matched-control group that did not develop a breakthrough infection. RESULTS: Lower levels of total binding and neutralizing antibodies were observed compared to the control group (6.900 [95% CI; 5.101-9.470] vs. 11.395 BAU/mL [8.627-15.050] [p=0.0301] and 26.6 [18.0-39.3] vs. 59.5 dilution titer-1 [32.3-110] [p=0.0042], respectively). The difference between breakthrough and control subjects was mostly observed for neutralizing antibodies before three months after the homologous booster administration (46.5 [18.2-119] vs. 381 [285-509] [p=0.0156]). Considering the measurement of total binding antibodies before 3 months, there was no significant difference (p=0.4375). CONCLUSIONS: In conclusion, our results showed that subjects that developed a breakthrough infection had lower levels of neutralizing and total binding antibodies compared to controls. The difference was mostly noticeable considering neutralizing antibodies, especially for infections occurring before 3 months after the booster administration.


Subject(s)
COVID-19 , Humans , Breakthrough Infections , BNT162 Vaccine , Antibodies, Neutralizing , Delivery of Health Care , Antibodies, Viral
6.
J Clin Virol ; 161: 105419, 2023 04.
Article in English | MEDLINE | ID: covidwho-2251532

ABSTRACT

BACKGROUND: A SARS-CoV-2+Flu A/B+RSV Combo Rapid test may be more relevant than Rapid Antigen Diagnostic (RAD) tests targeting only SARS-CoV-2 since we are facing a concurrent circulation of these viruses during the winter season. OBJECTIVES: To assess the clinical performance of a SARS-CoV-2+Flu A/B+RSV Combo test in comparison to a multiplex RT-qPCR. STUDY DESIGN: Residual nasopharyngeal swabs issued from 178 patients were included. All patients, adults and children, were symptomatic and presented at the emergency department with flu-like symptoms. Characterization of the infectious viral agent was done by RT-qPCR. The viral load was expressed as cycle threshold (Ct). Samples were then tested using the multiplex RAD test Fluorecare®à¸ SARS-CoV-2 & Influenza A/B & RSV Antigen Combo Test. Data analysis was carried out using descriptive statistics. RESULTS: The sensitivity of the test varies according to the virus, with the highest sensitivity observed for Influenza A (80.8.% [95%CI: 67.2 - 94.4]) and the lowest sensitivity observed for RSV (41.5% [95%CI: 26.2 - 56.8]). Higher sensitivities were observed for samples with high viral loads (Ct < 20) and decrease with low viral loads. The specificity for SARS-CoV-2, RSV and Influenza A and B was >95%. CONCLUSIONS: The Fluorecare® combo antigenic presents satisfying performance in real-life clinical setting for Influenza A and B in samples with high viral load. This could be useful to allow a rapid (self-)isolation as the transmissibility of these viruses increase with the viral load. According to our results, its use to rule-out SARS-CoV-2 and RSV infection is not sufficient.


Subject(s)
COVID-19 , Influenza, Human , Respiratory Syncytial Virus Infections , Adult , Child , Humans , Influenza, Human/diagnosis , SARS-CoV-2 , COVID-19/diagnosis , Respiratory Syncytial Virus Infections/diagnosis , Immunologic Tests , Sensitivity and Specificity
7.
Clin Chem Lab Med ; 2022 Nov 24.
Article in English | MEDLINE | ID: covidwho-2258854

ABSTRACT

This review is an integral part of the special issue for the 60 years of the journal Clinical Chemistry and Laboratory Medicine (CCLM). The aim of the review is to highlight the role of the clinical laboratory since the emergence of the "severe acute respiratory syndrome coronavirus 2" (SARS-CoV-2), which causes Coronavirus disease 2019 (COVID-19), with special focus on the contribution of the journal in generating knowledge in SARS-CoV-2 diagnosis. As of October 30, 2022, a total of 186 CCLM publications were dedicated to COVID-19. Of importance, major International Federation of Clinical Chemistry (IFCC) guidelines related to the diagnosis of COVID-19 were published in CCLM. Between early-2020 and late October 2022, COVID-19 publications represented around 27% of all articles in CCLM, highlighting the willingness of the editorial board to help the field in order to better describe and diagnose this new emerging disease. First launched in 1963 under the name "Zeitschrift für Klinische Chemie", the Journal was entirely devoted to clinical chemistry in the strict sense. The various topics published in relation to COVID-19 including its diagnosis, its impact on biochemical or hematological measures, as well as biosafety measures, is the perfect example that shows that the journal has greatly diversified over time.

8.
J Med Virol ; 2022 Sep 21.
Article in English | MEDLINE | ID: covidwho-2229914

ABSTRACT

Evidence about the long-term persistence of the booster-mediated immunity against Omicron is mandatory for pandemic management and deployment of vaccination strategies. A total of 155 healthcare professionals (104 COVID-19 naive and 51 with a history of SARS-CoV-2 infection) received a homologous BNT162b2 booster. Binding antibodies against the spike protein and neutralizing antibodies against Omicron were measured at several time points before and up to 6 months after the booster. Geometric mean titers of measured antibodies were correlated to vaccine efficacy (VE) against symptomatic disease. Compared to the highest response, a significant 10.2- and 11.5-fold decrease in neutralizing titers was observed after 6 months in participants with and without history of SARS-CoV-2 infection. A corresponding 2.5- and 2.9-fold decrease in binding antibodies was observed. The estimated T1/2 of neutralizing antibodies in participants with and without history of SARS-CoV-2 infection was 42 (95% confidence interval [CI]: 25-137) and 36 days (95% CI: 25-65). Estimated T1/2 were longer for binding antibodies: 168 (95% CI: 116-303) and 139 days (95% CI: 113-180), respectively. Both binding and neutralizing antibodies were strongly correlated to VE (r = 0.83 and 0.89). However, binding and neutralizing antibodies were modestly correlated, and a high proportion of subjects (36.7%) with high binding antibody titers (i.e., >8434 BAU/ml) did not have neutralizing activity. A considerable decay of the humoral response was observed 6 months after the booster, and was strongly correlated with VE. Our study also shows that commercial assays available in clinical laboratories might require adaptation to better predict neutralization in the Omicron era.

9.
Int J Lab Hematol ; 2022 Oct 12.
Article in English | MEDLINE | ID: covidwho-2223347

ABSTRACT

INTRODUCTION: Lupus anticoagulant (LA) testing requires normal pooled plasma (NPP) in performing mixing studies and can be used for normalized ratios of clotting times (CTs). The aims were to demonstrate whether significant differences in clotting times between two batches of a same commercial NPP (CRYOcheck™) directly affect NPP-based cut-off values. METHODS: Diluted Russell Viper venom time (DRVVT) and activated partial thromboplastin time (aPTT) were used for LA testing. Screening, mixing and confirm tests were performed with Stago® instruments and reagents. Two batches of commercial NPP (A1291 and A1301 from CRYOcheck™; frozen) were compared in the determination of cut-off values. Cut-off values were defined as 99th percentile values of 60 healthy donors and compared with Mann-Whitney U test. RESULTS: Cut-off values obtained with the two NPP batches were significantly different for DRVVT (screen normalized ratio: 1.09 vs. 1.24, screen mix: 41.9 s vs. 38.9 s; index of circulating anticoagulant: 5.0 vs. 8.4; all had p-value <.001). On the contrary, no significant differences were observed for aPTT (screen normalized ratio: 1.32 vs. 1.34; p-value = .4068, screen mix: 37.8 s vs. 38.1 s; p-value = .1153) except for index of circulating anticoagulant: 9.6 versus 10.4 (p-value <.05). CONCLUSION: This study demonstrates that differences between two commercial NPP batches produced by a same manufacturer influenced LA cut-off values used for mixing studies and normalized ratios. Adequate cut-off setting, taking into account NPP CTs, is important to provide accurate conclusion about the presence or absence of a LA and avoid potential clinical impact.

10.
Vaccines (Basel) ; 10(12)2022 Nov 30.
Article in English | MEDLINE | ID: covidwho-2143800

ABSTRACT

BACKGROUND: in this report, we describe the case of an 83-year-old woman vaccinated with ChadOx1 nCoV-19 who developed a so-called vaccine-induced thrombosis with thrombocytopenia syndrome and who did not develop any antibodies against the spike protein of SARS-CoV-2 at 30 days following the administration of her first dose of ChadOx1 nCoV-19. Experimental section: two serum samples from the patient and 5 serum samples from 5 control individuals having received the two-dose regimen vaccination with ChadOx1 nCoV-19 were evaluated. In order to investigate the lack of response to the vaccination, a cell model was developed. This model permits to evaluate the interaction between responsive cells (A549) possessing the Coxsackievirus and Adenovirus Receptor (CAR), a defined concentration of ChadOx1 nCoV-19 and serial dilution of the patient or the control serum. The aim was to assess the impact of these sera on the production of the spike (S) protein induced by the transfection of the genetic material of ChadOx1 nCoV-19 into the A549 cells. The S protein is measured in the supernatant using an ELISA technique. RESULTS: interestingly, the serum from the patient who developed the vaccine-induced thrombosis with thrombocytopenia syndrome impaired the production of S protein by the A549 cells transfected with ChadOx1 nCoV-19. This was not observed with the controls who did not interfere with the transfection of ChadOx1 nCoV-19 into A549 cells since the S protein is retrieved in the supernatant fraction. CONCLUSION: based on the data coming from the clinical and the cell model information, we found a possible explanation on the absence of antibody response in our patient. She has, or has developed, characteristics that prevent the production of the S protein in contrast to control subjects. We were not able to investigate the entire mechanism behind this resistance which deserve further investigations. A link between this resistance and the development of the thrombosis with thrombocytopenia syndrome following vaccination with ChadOx1 nCoV-19 cannot be excluded.

11.
Front Med (Lausanne) ; 8: 780750, 2021.
Article in English | MEDLINE | ID: covidwho-2009871

ABSTRACT

Critical COVID-19, like septic shock, is related to a dysregulated systemic inflammatory reaction and is associated with a high incidence of thrombosis and microthrombosis. Improving the understanding of the underlying pathophysiology of critical COVID-19 could help in finding new therapeutic targets already explored in the treatment of septic shock. The current study prospectively compared 48 patients with septic shock and 22 patients with critical COVID-19 regarding their clinical characteristics and outcomes, as well as key plasmatic soluble biomarkers of inflammation, coagulation, endothelial activation, platelet activation, and NETosis. Forty-eight patients with matched age, gender, and co-morbidities were used as controls. Critical COVID-19 patients exhibited less organ failure but a prolonged ICU length-of-stay due to a prolonged respiratory failure. Inflammatory reaction of critical COVID-19 was distinguished by very high levels of interleukin (IL)-1ß and T lymphocyte activation (including IL-7 and CD40L), whereas septic shock displays higher levels of IL-6, IL-8, and a more significant elevation of myeloid response biomarkers, including Triggering Receptor Expressed on Myeloid cells-1 (TREM-1) and IL-1ra. Subsequent inflammation-induced coagulopathy of COVID-19 also differed from sepsis-induced coagulopathy (SIC) and was characterized by a marked increase in soluble tissue factor (TF) but less platelets, antithrombin, and fibrinogen consumption, and less fibrinolysis alteration. In conclusion, COVID-19 inflammation-induced coagulopathy substantially differs from SIC. Modulating TF release and activity should be evaluated in critical COVID-19 patients.

12.
Viruses ; 14(8)2022 07 28.
Article in English | MEDLINE | ID: covidwho-1969497

ABSTRACT

The diagnostic of SARS-CoV-2 infection relies on reverse transcriptase polymerase chain reactions (RT-PCRs) performed on nasopharyngeal (NP) swabs. Nevertheless, false-negative results can be obtained with inadequate sampling procedures, making the use of other biological matrices worthy of investigation. This study aims to evaluate the kinetics of serum N antigens in severe and non-severe patients and compare the clinical performance of serum antigenic assays with NP RT-PCR. Ninety patients were included in the study and monitored for several days. Disease severity was determined according to the WHO clinical progression scale. Serum N antigen levels were measured with a chemiluminescent assay (CLIA) and the Single Molecular Array (Simoa) assay. Viremia thresholds for severity were determined and proposed. In severe patients, the peak antigen response was observed 7 days after the onset of symptoms, followed by a decline. No real peak response was observed in non-severe patients. Severity thresholds for the Simoa and the CLIA provided positive likelihood ratios of 30.0 and 10.9 for the timeframe between day 2 and day 14, respectively. Sensitive detection of N antigens in serum may thus provide a valuable new marker for COVID-19 diagnosis and evaluation of disease severity. When assessed during the first 2 weeks since the onset of symptoms, it may help in identifying patients at risk of developing severe COVID-19 to optimize better intensive care utilization.


Subject(s)
COVID-19 , COVID-19/diagnosis , COVID-19 Testing , Humans , Immunologic Tests , SARS-CoV-2 , Sensitivity and Specificity , Severity of Illness Index
13.
Biomolecules ; 12(8)2022 07 27.
Article in English | MEDLINE | ID: covidwho-1969083

ABSTRACT

Background: Neutrophil extracellular traps' (NETs') formation is a mechanism of defense that neutrophils deploy as an alternative to phagocytosis, to constrain the spread of microorganisms. Aim: The aim was to evaluate biomarkers of NETs' formation in a patient cohort admitted to intensive care unit (ICU) due to infection. Methods: Forty-six septic shock patients, 22 critical COVID-19 patients and 48 matched control subjects were recruited. Intact nucleosomes containing histone 3.1 (Nu.H3.1), or citrullinated histone H3R8 (Nu.Cit-H3R8), free citrullinated histone (Cit-H3), neutrophil elastase (NE) and myeloperoxidase (MPO) were measured. Results: Significant differences in Nu.H3.1 and NE levels were observed between septic shock and critical COVID-19 subjects as well as with controls (p-values < 0.05). The normalization of nucleosome levels according to the neutrophil count improved the discrimination between septic shock and critical COVID-19 patients. The ratio of Nu.Cit-H3R8 to Nu.H3.1 allowed the determination of nucleosome citrullination degree, presumably by PAD4. Conclusions: H3.1 and Cit-H3R8 nucleosomes appear to be interesting markers of global cell death and neutrophil activation when combined. Nu.H3.1 permits the evaluation of disease severity and differs between septic shock and critical COVID-19 patients, reflecting two distinct potential pathological processes in these conditions.


Subject(s)
COVID-19 , Extracellular Traps , Shock, Septic , Biomarkers/metabolism , Extracellular Traps/metabolism , Histones/metabolism , Humans , Neutrophils/metabolism , Nucleosomes/metabolism , Shock, Septic/metabolism
14.
Viruses ; 14(7)2022 07 02.
Article in English | MEDLINE | ID: covidwho-1917797

ABSTRACT

(1) Background: High immunosuppressive regimen in lung transplant recipients (LTRs) hampers the immune response to vaccination. We prospectively investigated the immunogenicity of heterologous ChAdOx1 nCoV-19-BNT162b2 mRNA vaccination in an LTR cohort. (2) Methods: Forty-nine COVID-19 naïve LTRs received a two-dose regimen ChAdOx1 nCoV-19 vaccine. A subset of 32 patients received a booster dose of BNT162b2 mRNA vaccine 18 weeks after the second dose. (3) Results: Two-doses of ChAdOx1 nCoV-19 induced poor immunogenicity with 7.2% seropositivity at day 180 and low neutralizing capacities. The BNT162b2 mRNA vaccine induced significant increases in IgG titers with means of 197.8 binding antibody units per milliliter (BAU/mL) (95% CI 0-491.4) and neutralizing antibodies, with means of 76.6 AU/mL (95% CI 0-159.6). At day 238, 32.2% of LTRs seroconverted after the booster dose. Seroneutralization capacities against Delta and Omicron variants were found in only 13 and 9 LTRs, respectively. Mycophenolate mofetil and high-dose corticosteroids were associated with a weak serological response. (4) Conclusions: The immunogenicity of a two-dose ChAdOx1 nCoV-19 vaccine regimen was very poor in LTRs, but was significantly enhanced after the booster dose in one-third of LTRs. In immunocompromised individuals, the administration of a fourth dose may be considered to increase the immune response against SARS-CoV-2.


Subject(s)
BNT162 Vaccine , ChAdOx1 nCoV-19 , Lung Transplantation , Transplant Recipients , Antibodies, Viral , BNT162 Vaccine/immunology , COVID-19/prevention & control , ChAdOx1 nCoV-19/immunology , Humans
16.
Bio Protoc ; 12(7): e4377, 2022 Apr 05.
Article in English | MEDLINE | ID: covidwho-1836289

ABSTRACT

Neutralizing antibodies (NAbs) are of particular importance because they can prevent binding of the receptor binding domain (RBD) of the spike protein (S protein) to the angiotensin-converting enzyme 2 (ACE2) receptor present at the surface of human cells, preventing virus entry into the host cells. The gold standard method for detection of NAbs is the plaque reduction neutralization test (PRNT). Based on the measurement of cell lysis due to viral infection, this test is able to detect antibodies that prevent cell infection (Muruato et al., 2020; Lau et al., 2021). This technique requires the use of live pathogens, i.e., SARS-CoV-2 in this case, and must be done in a biosafety level 3 (BL3) laboratory. In addition, it requires expensive installations, skillful and meticulous staff, and a high workload, which prevents its wide implementation even in research laboratories. A SARS-CoV-2 pseudovirus will express the S protein responsible for cell entrance, but will not express the pathogenic genetic material of the virus, making them less dangerous for laboratory staff and the environment. Graphic abstract.

18.
Viruses ; 14(4)2022 03 22.
Article in English | MEDLINE | ID: covidwho-1753695

ABSTRACT

Rapid antigen detection (RAD) tests are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC), presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One hundred and twenty samples were selected and tested with both RT-qPCR and six commercial RAD tests that are commonly sold in Belgian pharmacies. Of these, direct whole-genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron (BA.1 and BA.1.1 sub-lineages, respectively). The sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) ranged from 70.0% to 92.9% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25, corresponding to <4.9 log10 copies/mL), only the Roche RAD test showed acceptable performances for the Delta strains (80.0%), while poor performances were observed for the other RAD tests (20.0% to 40.0%). All the tested devices had poor performances for the Omicron samples with a low viral load (0.0% to 23.1%). The poor performances observed with low viral loads, particularly for the Omicron strain, is an important limitation of RAD tests, which is not sufficiently highlighted in the instructions for use of these devices.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Nucleocapsid Proteins/genetics , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics
19.
Frontiers in medicine ; 8, 2021.
Article in English | EuropePMC | ID: covidwho-1661044

ABSTRACT

Critical COVID-19, like septic shock, is related to a dysregulated systemic inflammatory reaction and is associated with a high incidence of thrombosis and microthrombosis. Improving the understanding of the underlying pathophysiology of critical COVID-19 could help in finding new therapeutic targets already explored in the treatment of septic shock. The current study prospectively compared 48 patients with septic shock and 22 patients with critical COVID-19 regarding their clinical characteristics and outcomes, as well as key plasmatic soluble biomarkers of inflammation, coagulation, endothelial activation, platelet activation, and NETosis. Forty-eight patients with matched age, gender, and co-morbidities were used as controls. Critical COVID-19 patients exhibited less organ failure but a prolonged ICU length-of-stay due to a prolonged respiratory failure. Inflammatory reaction of critical COVID-19 was distinguished by very high levels of interleukin (IL)-1β and T lymphocyte activation (including IL-7 and CD40L), whereas septic shock displays higher levels of IL-6, IL-8, and a more significant elevation of myeloid response biomarkers, including Triggering Receptor Expressed on Myeloid cells-1 (TREM-1) and IL-1ra. Subsequent inflammation-induced coagulopathy of COVID-19 also differed from sepsis-induced coagulopathy (SIC) and was characterized by a marked increase in soluble tissue factor (TF) but less platelets, antithrombin, and fibrinogen consumption, and less fibrinolysis alteration. In conclusion, COVID-19 inflammation-induced coagulopathy substantially differs from SIC. Modulating TF release and activity should be evaluated in critical COVID-19 patients.

SELECTION OF CITATIONS
SEARCH DETAIL